| Parameter | Specification | |:----------|:--------------| | Operating Voltage | DC 12V ±10% | | Unlock Current | ≤1000mA | | Standby Current | ≤60mA | | User Capacity | 1000 standard users | | Read Distance | 5~15cm | | Supported Card Type | EM 125kHz standard card | | Working Temperature | -10°C to 70°C | | Working Humidity | 10% to 90% | | Dimensions | 117 × 117 × 21 mm | | Unlock Relay Rating | 12VDC / 2A | | Alarm Output | 20A max |
The device automatically assigns the next available User ID slot.
To modify users, door timers, or security settings, you must enter . V2000-c Rfid Access Control User Manual
Fail-secure locks require electricity to unlock. They remain locked during a power outage. Connect Power Supply (+12V) to Keypad COM . Lock Connection: Connect Keypad NO to Lock (+).
The V2000-C tracks users via numbered from 1 to 2000 . Assigning specific User IDs is highly recommended so you can delete lost cards without needing the physical card in hand. Adding Users (Card or Fob Only) Enter programming mode. Press 1 . Enter a unique User ID (e.g., 0001 to 2000 ) followed by # . They remain locked during a power outage
To customize the hardware behavior, the V2000-c features specific jumper settings:
The back of the V2000-C features a wiring block. Correct wiring prevents short circuits and equipment damage. Wire Color / Label Description Power Positive Connects to 12V DC positive power supply GND Power Negative Connects to power supply ground PUSH Low-level Trigger Connects to exit button or power supply push terminal OPEN Door Button Connects to one side of the exit button NC Normally Closed Connects to the positive side of a Magnetic Lock NO Normally Open Connects to the positive side of an Electric Strike COM Common Terminal The V2000-C tracks users via numbered from 1 to 2000
Indoor or sheltered outdoor use (Operating temperature: -10°C to 55°C) 2. Wiring Diagram and Installation