Vlc 1600 Datasheet ((free)) 📍

Any legitimate VLC 1600 datasheet will include a prominent . A 1600 mW (Class 4) laser is extremely hazardous.

16 Universal Inputs (10-bit resolution legacy / 16-bit high-resolution "-E" models) Zero control outputs (dedicated input monitoring device) Auxiliary Power Supply

+--------------------------------------------------------+ | Alerton VisualLogic Toolset | | (DDC Programming / Custom Control Logic) | +---------------------------+----------------------------+ | Compiles To BD4 Format v +--------------------------------------------------------+ | VLC-1600 Field Memory | | - 100ms Logical Execution Loop Time | | - 512 MB Secure Boot Flash Storage | +---------------------------+----------------------------+ | Configured via Input 0 (IN-0) v +--------------------------------------------------------+ | Intelligent Wall Sensor Interface | | (Supports Microset, Microset II, Microset 4) | +--------------------------------------------------------+

| Parameter | Symbol | Rating | Unit | |-----------|--------|--------|------| | Optical Output Power (CW) | P( opt) | 1600 | mW | | Forward Current (CW) | I( F) | 2400 | mA | | Reverse Voltage (Laser) | V( R) | 2 | V | | Operating Temperature | T( op) | -20 to +70 | °C | | Storage Temperature | T(_stg) | -40 to +85 | °C | | Soldering Temperature (5 sec) | – | 260 | °C | vlc 1600 datasheet

Expect graphs showing:

It is crucial to note that the VLC-1600 is designed primarily as an and, according to official Honeywell documentation, "has no control outputs". The VLC-1600 offers 16 universal inputs that are jumper-selectable to accept a variety of signal types. The older VLC-1600 model features 16 10-bit universal inputs . Input 0 is specifically designed for a BACtalk Microset sensor, while inputs 1-15 can be configured for thermistor, dry contact, 0-5 VDC, 0-10 VDC, or 4-20 mA signals. Some inputs also support pulse-type signals.

Legacy variants operate up to 76.8 Kbps, while modern "E" versions feature auto-baud switching across 9.6, 19.2, 38.4, 76.8, and 115.2 Kbps. Built-in communication status LEDs provide real-time field troubleshooting indicators. DDC Programming with VisualLogic Any legitimate VLC 1600 datasheet will include a prominent

Thermistor, dry contact, 0–5 V, 0–10 V, 4–20 mA, pulse No control outputs; 24 VDC @ 100 mA for sensors No control outputs; 20 VDC @ 100 mA for sensors Communications BACnet MS/TP up to 76.8 Kbps BACnet MS/TP up to 115.2 Kbps Processor Motorola AZ60 with on-board flash 32-bit ARM Cortex-M4F, 80 MHz Memory Non-volatile flash storage 512 MB non-volatile flash Dimensions 4.90" H x 5.45" W x 1.40" D 4.9" H x 5" W x 1.4" D Core Functionalities

VLC 1600 datasheet, optical output power, forward current, beam divergence, laser diode specifications, 1600 nm, visible light communication, thermal management, L-I-V curve, absolute maximum ratings.

The "VLC-1600" most frequently refers to a native BACnet monitoring device manufactured by Alerton, which is now a brand under Honeywell International. As a dedicated input monitoring device, its primary function is not to control equipment directly but to act as a powerful data acquisition module for various sensor types, integrating seamlessly into a larger Building Management System (BMS) or HVAC (Heating, Ventilation, and Air Conditioning) network. The standard VLC-1600 has no control outputs; it is purely an input device. The VLC-1600 offers 16 universal inputs that are

: EIA-485 (RS-485) over standard Twisted Shielded Pair (TSP) cabling.

She built the test board in the late hours, solder smoke curling like incense. The VLC 1600 sat in its footprint: small, mute, waiting. She fed it 1.8 volts — the lower edge of its comfortable sleep — and watched the oscilloscope like a star chart. At first nothing happened. Then the scope traced a ripple, a waveform that matched the timing diagram in the datasheet so perfectly Maya laughed out loud: her faith rewarded by cold, exact numbers.

At nominal power (1600 mW) and case temperature (25°C), the datasheet typically states MTTF > 10,000 hours . Derate power by 50% for every 10°C above 25°C to maintain lifetime.

For more detailed installation diagrams and software configuration, refer to the Alerton VLC-1600 Technical Data .