The parameter lock ( LCK ) stops unauthorized changes to your system configuration. LCK = 00 : All parameters are open for modification. LCK = 01 : Only the primary Set Value (SV) can be adjusted. LCK = 11 : All internal menus are completely locked. Step-by-Step Auto-Tuning Guide xmtg-2000 temperature controller manual pdf
The XMTG-2000 is part of the XMT- 2000 series, which features a four-digit digital LED display for showing Process Value (PV) and Set Value (SV). It utilizes AI (Artificial Intelligence) PID algorithms for precise thermal regulation. XMTG-2000 Dimensions: Typically 48mm × 48mm (front panel) Display: 4-digit LED display (PV/SV) Key Feature: PID/On-Off control & Manual function. 2. Technical Specifications According to common specifications, the XMTG-2000 offers:
| Code | Name | Explanation | Common Setting | |------|------|-------------|----------------| | | Alarm 1 value | Triggers relay when PV exceeds SV+AL1 | 5.0 (for 5° deviation) | | P | Proportional band | Heat output % per error degree. Lower = more aggressive | 30.0 (start here) | | I | Integral time | Eliminates steady-state error. Smaller = faster | 240 seconds | | D | Derivative time | Prevents overshoot. Smaller = faster reaction | 60 seconds | | T | Cycle time | Relay models: 20 sec; SSR models: 2 sec | 20 (relay) / 2 (SSR) | | SC | Sensor correction | Offset to match a reference thermometer | 0.0 (unless calibrating) | | LCK | Lock code | 0=unlock; 1=lock SV only; 2=lock all parameters | 0 | A: Yes, you can download the XMTG-2000 temperature
The is a widely used, intelligent digital instrument found in modern industrial automation . It relies on advanced microcomputers to manage temperature baselines across various setups, including plastics machinery, food packaging, and heat-treatment ovens.
Let the system run through three complete on-off cycles without changing anything. The controller will save the new PID values and turn off the indicator light when finished. Diagnostic Troubleshooting Codes Error Code Root Cause Corrective Actions Input Sensor Open-Circuit Check for broken sensor wires or failed thermocouple tips. LLLL Input Sensor Short-Circuit LCK = 01 : Only the primary Set Value (SV) can be adjusted
The light indicator on the front panel will begin blinking. This shows that the tuning cycle has started.